cmd: raw commands#

Send a raw command, with the options of nvme admin-passthru and nvme io-passthru:

xnvme cmd-admin --help
Usage: xnvme cmd-admin <uri> [OPTIONS]

Send a user-defined command to the device at <uri>, any xNVMe URI: a
character or block device, a BDF, or a fabrics address. The options are
those of nvme admin-passthru, with the same names and letters:

  -O, --opcode=NUM       -f, --flags=NUM        -p, --prefill=NUM
  -R, --rsvd=NUM         -n, --namespace-id=NUM -l, --data-len=NUM
  -m, --metadata-len=NUM -2, --cdw2=NUM         -3, --cdw3=NUM
  -4 .. -9, --cdw10=NUM .. --cdw15=NUM          -i, --input-file=FILE
  -M, --metadata=FILE    -b, --raw-binary       -s, --show-command
  -d, --dry-run          -r, --read             -w, --write
  -T, --latency          -o, --output-format=FMT -v, --verbose
  --no-retries

but -t, --timeout, as the synchronous path has no per-command timeout. Then,
choosing the path: --be, --admin, --sync, --async, --dev-nsid and
--homi-id or --shm_id.
xnvme cmd-io --help
Usage: xnvme cmd-io <uri> [OPTIONS]

Send a user-defined command to the device at <uri>, any xNVMe URI: a
character or block device, a BDF, or a fabrics address. The options are
those of nvme io-passthru, with the same names and letters:

  -O, --opcode=NUM       -f, --flags=NUM        -p, --prefill=NUM
  -R, --rsvd=NUM         -n, --namespace-id=NUM -l, --data-len=NUM
  -m, --metadata-len=NUM -2, --cdw2=NUM         -3, --cdw3=NUM
  -4 .. -9, --cdw10=NUM .. --cdw15=NUM          -i, --input-file=FILE
  -M, --metadata=FILE    -b, --raw-binary       -s, --show-command
  -d, --dry-run          -r, --read             -w, --write
  -T, --latency          -o, --output-format=FMT -v, --verbose
  --no-retries

but -t, --timeout, as the synchronous path has no per-command timeout. Then,
choosing the path: --be, --admin, --sync, --async, --dev-nsid and
--homi-id or --shm_id.
xnvme cmd-iov --help
Usage: xnvme cmd-iov <uri> [OPTIONS]

Send a user-defined command to the device at <uri>, any xNVMe URI: a
character or block device, a BDF, or a fabrics address. The options are
those of nvme io-passthru, with the same names and letters:

  -O, --opcode=NUM       -f, --flags=NUM        -p, --prefill=NUM
  -R, --rsvd=NUM         -n, --namespace-id=NUM -l, --data-len=NUM
  -m, --metadata-len=NUM -2, --cdw2=NUM         -3, --cdw3=NUM
  -4 .. -9, --cdw10=NUM .. --cdw15=NUM          -i, --input-file=FILE
  -M, --metadata=FILE    -b, --raw-binary       -s, --show-command
  -d, --dry-run          -r, --read             -w, --write
  -T, --latency          -o, --output-format=FMT -v, --verbose
  --no-retries

but -t, --timeout, as the synchronous path has no per-command timeout. Then,
choosing the path: --be, --admin, --sync, --async, --dev-nsid and
--homi-id or --shm_id, and --vec-cnt=NUM, the number of equal segments the data is sent in.